handsonact [2024/03/03 10:54] – [3. Act #3 (1.75h, Tue. Mar.5):] nuicisehandsonact [2024/03/03 11:00] (current) – [5. Act #5 (1.75h, Thu. Mar. 7):] nuicise
Line 36: Line 36:
   * **Group A**: setup and measure the speed of light in the optical fiber (convert from timing to distance; refer to the refractive index of the optical fiber)   * **Group A**: setup and measure the speed of light in the optical fiber (convert from timing to distance; refer to the refractive index of the optical fiber)
   * **Group B**: setup and measure the profile of a light source (eg. from LED transport through an optical fiber. Refer to the so-called numerical aperture of the fiber )   * **Group B**: setup and measure the profile of a light source (eg. from LED transport through an optical fiber. Refer to the so-called numerical aperture of the fiber )
-  * **Group C**+  * **Group C**: Setup and measure the spectra of the light source with optical filters
 ===== 5. Act #5 (1.75h, Thu. Mar. 7): ===== ===== 5. Act #5 (1.75h, Thu. Mar. 7): =====
  Work in combination of Scintillator, wavelength shifting fiber and photosensor; concept of muon counter; NIM modules to use: discriminator, scaler, coincidence (and delay if needed)  Work in combination of Scintillator, wavelength shifting fiber and photosensor; concept of muon counter; NIM modules to use: discriminator, scaler, coincidence (and delay if needed)
 +  * **Group A** use scintillator bar; wavelength shifting fiber polishing and glue to be fitted in the optical connector to single MPPC 
 +  * **Group B** use laser-cutted plate for coupling wavelength shifting fiber to sensor.  
 +  * **Group C** use scintillator cube; observe signal; check the rate; compare the signal with wavelength shifting fiber 
 ===== 6. Act #6 (2.0h, Thu. Mar. 7): ===== ===== 6. Act #6 (2.0h, Thu. Mar. 7): =====
   *  Check the coincidence rate of muons and see whether it is consistent with what we expect. Try to tighten or loosen the threshold in the trigger pattern and see how the result changed.    *  Check the coincidence rate of muons and see whether it is consistent with what we expect. Try to tighten or loosen the threshold in the trigger pattern and see how the result changed. 